牌号简介 About |
---|
CALIBRE™ 2060-6 聚碳酸酯树脂用于涉及蒸气灭菌或者环氧乙烷灭菌的医疗领域 —— 尽管在这些应用领域的适用性取决于高压灭菌周期和温度的设定。CALIBRE 2060-6具有特别优异的透明度、耐热性能、抗冲击强度以及加工性能,并且其污染程度低。CALIBRE 2060-10树脂已经根据ISO 10993 (医疗器械生物学评价)经过了生物相容性测试,适合用于获准的医疗应用领域。 主要特性: 符合ISO 10993 的要求 应用领域: 医疗应用 CALIBRE™ 2060-6 Polycarbonate resin is used in medical applications involving steam or ethylene oxide sterilization - though suitability for use in these applications is dependent upon autoclave cycle times and temperatures. CALIBRE 2060-6 provides exceptional clarity, heat resistance, impact strength, and processability, and has low contamination levels. The CALIBRE 2000 series of resins have been evaluated by certain biocompatibility tests based on on ISO 10993-1 (Biological Evaluation of Medical Devices) and are suitable for use in approved medical applications. Main Characteristics: Tested under ISO 10993 and USP FDA 21 CFR 177.1580 Applications: Medical applications |
技术参数 Technical Data | |||
---|---|---|---|
物理性能 PHYSICAL |
额定值 Nominal Value |
单位 Units |
测试方法 Test Method |
密度 Density |
1.20 | g/cm³ | ASTM D792 |
密度 Density |
1.20 | g/cm³ | ISO 1183/A |
熔体质量流动速率 Melt Flow Rate |
|||
300℃,1.20kg 300℃,1.20kg |
6.0 | g/10min | ISO 1133 |
300℃,1.20kg 300℃,1.20kg |
6.0 | g/10min | ASTM D1238 |
收缩率 Shrinkage rate |
|||
MD MD |
0.50 to 0.70 | % | ISO 294-4 |
MD MD |
% | ASTM D955 | |
吸水率 Water absorption rate |
|||
平衡,23℃,50% RH Equilibrium, 23 ℃, 50% RH |
% | ASTM D570 | |
平衡,23℃,50% RH Equilibrium, 23 ℃, 50% RH |
% | ISO 62 | |
23℃,24hr 23℃,24hr |
% | ASTM D570 | |
23℃,24hr 23℃,24hr |
% | ISO 62 | |
冲击性能 IMPACT |
额定值 Nominal Value |
单位 Units |
测试方法 Test Method |
悬臂梁缺口冲击强度 Impact strength of cantilever beam notch |
|||
23℃ 23℃ |
J/m | ASTM D256-A | |
23℃ 23℃ |
kJ/m² | ISO 180-A | |
23℃ 23℃ |
ASTM D256 | ||
悬臂梁无缺口冲击强度 Notched impact strength of cantilever beam |
|||
23℃ 23℃ |
ISO 180 | ||
装有测量仪表的落镖冲击 Dart impact equipped with measuring instruments 6 |
|||
23℃ 23℃ 6 |
J | ASTM D3763 | |
拉伸冲击强度 Tensile impact strength |
kJ/m² | ASTM D1822 | |
机械性能 MECHANICAL |
额定值 Nominal Value |
单位 Units |
测试方法 Test Method |
拉伸模量 Tensile modulus 3 |
MPa | ASTM D638 | |
拉伸模量 Tensile modulus |
MPa | ISO 527-2/50 | |
拉伸强度 tensile strength |
|||
断裂 fracture |
MPa | ISO 527-2/50 | |
断裂 fracture 3 |
MPa | ASTM D638 | |
屈服 yield 3 |
MPa | ASTM D638 | |
屈服 yield |
MPa | ISO 527-2/50 | |
拉伸应变 Tensile strain 4 |
|||
断裂 fracture |
% | ISO 527-2/50 | |
断裂 fracture 4 |
% | ASTM D638 | |
弯曲模量 Bending modulus 4 |
MPa | ASTM D790 | |
弯曲模量 Bending modulus 5 |
MPa | ISO 178 | |
弯曲强度 bending strength 4 |
MPa | ASTM D790 | |
弯曲强度 bending strength 5 |
MPa | ISO 178 | |
泰伯耐磨性 Taber abraser |
% | ASTM D1044 | |
洛氏硬度 Rockwell hardness |
ASTM D785 | ||
M 级 M-level |
ASTM D785 | ||
R 级 R-level |
ASTM D785 |
备注 |
---|
1 Biocompatibility testing following ISO Guidelines 10993 has been completed on select classic resins in this series. Please consult Styron for details. ISO guidelines include a sensitization test. |
2 一般属性:这些不能被视为规格。 |
3 2.0 in/min |
4 方法 I (三点负荷), 0.079 in/min |
5 0.079 in/min |
6 11.1 ft/sec |
【新闻资讯】查看全部
杜邦扩充其行业领先的EIS应用解决方案组合
2022-09-22 扫描上图二维码,可以免费下载 搜料 APP 在2022年即将举行的K展会之前,杜邦交通与材料事业部宣布,其已获得UL最新的EIS F级CRZ200标准认证。在CRZ200标准中,有四种类型的无卤阻燃( |
【免责声明】 广州搜料信息技术有限公司保留所有权利。 此数据表中的信息由搜料网soliao.com从该材料的生产商处获得。搜料网soliao.com尽最大努力确保此数据的准确性。 但是搜料公司对这些数据值及建议等给用户带来的不确定因素和后果不承担任何责任,并强烈建议在最终选择材料前,就数据值与材料供应商进行验证。 |